• CEN03 type is without timer (also could be controlled by Programmable Logic Controller) and has to work with volume distributors.
• With CAB or CBB type volume distributor, oil will feed during operation time.
• With CDB or T type volume distributor, oil will feed during interval time.
• The discharge volume is fixed. The lubrication points of volume distributor supply a fixed flow of oil.
• It has a spark-eliminator inside to prevent the sparks producing when the electric current is running.
• The spark-eliminator can avoid PLC (Programmable Logic Controller) being interfered.
• CEN03 type has a pressure switch device and been set up as 8kg/㎝², which assures the oil volume of lubrication point and check if the piping works normally.
• The standard specification is NC (Normal Close) contact, which means if the pressure is abnormal, it will have signal. NO (Normal Open) contact is available on request.
• It has a float switch that can detect the oil volume. When oil is lower than the minimum level, the float switch will automatically send a continuous signal.
• Made in taiwan